–12– AN-639 What are the connections for 3-phase 4-wire wye service (with three voltage sensors)? ANTIALIASING FILTER ANTIALIASING FILTER ANTIALIASING FILTER SOURCE PHASE A PHASE B PHASE C VAP I AB I AN I BP I BN I CP I CN VBP VCP VN LOAD CT CT CT R B R B R B R A R B VR C F R A R B VR C F R A R F R B VR C F CF Figure 6. 4-Wire Wye Service Connections with Three Voltage Sensors Active Power V V I